Strip size supported model MR182-A
Strip size supported model
MR182-A
MR182-A
A fully automatic type of machine in which a work sheet is loaded/unloaded automatically. Equipped with a magazine stocker and laser marker, this model is best suited for IC substrate continuity/insulation test.
Applications
Application examples |
|
---|
Max. work sheet size | X120 x Y250mm |
---|---|
Max. test fixture size | When not rotating:X100 x Y100mm |
Work sheet transfer | Loading:Automatic Unloading:Automatic |
Dimensions
Specifications
Model | MR182-A | |
---|---|---|
Type | MR182-A-DM5 | |
Application examples | IC substrate | |
Test capability | Max. number of test points | Upper head:2,046 / Lower head:2,046 |
Work sheet size | X70~120mm / Y100~250mm | |
Max. test range*1 | Range excluding an area of X2.0 x Y4.0mm from four corners of work sheet | |
Max. test fixture size | When rotating: No rotation / When not rotating : X100 x Y100mm | |
Positioning accuracy*2 | ±5μm | |
Test specifications | Determination method | Open/short (pass/fail determined based on specified resistance value) |
Open test*2 | Test range: 2 wire test 10Ω~ 10kΩ (0.5mA,10mA) 4 wire test 1mΩ~ 500Ω (10mA, 40mA, 100mA) |
|
Open voltage: 15V ~ 50V | ||
Test accuracy: 2 wire test ±10% (50Ω~ 10kΩ), ±5Ω (10Ω~ 50Ω) 4 wire test ±10% (1mΩ~ 500Ω) |
||
Short test*2 | Test range: 100kΩ~ 100MΩ | |
Test voltage: 50V ~ 250V | ||
Test accuracy: ±10% | ||
Options | μ Short test, Spark detection, Heating test, Non contact test | |
Work sheet transfer | Loading / Unloading | Automatic |
Image processing | Camera view | X2.4 x Y1.8mm (standard) |
Pattern detection | Pattern recognition via grayscale | |
Illumination type | Transmission light, reflection light | |
Hardware | Interface | LAN・USB |
Display | 15 inch LCD with touch panel | |
Software | OS | Windows7 |
Production support function | Automatic fixture correction, output of test result log, automatic retry test, fixture stroke count | |
Usage environment | Weight | Approx. 3,700kg |
Power supply | 1-phase, 180 to 240V AC, 50/60Hz, 6kVA | |
Dry air | 0.5MPa |
- The actual test range varies depending on the fixture shape, holding range, etc.
- Data taken from our performance test.